SECTION SEVEN: GRQ2 REMOTE SOFTWARE INSTALLATION
You may connect and control up to eight Graphi-Q2s from one COM port. If your computer offers two
COM ports, you may set up two distinct Graphi-Q2 networks of up to eight units each—one for each port.
Simply connect units in series from the SERIAL OUT jack of the previous unit to the SERIAL IN jack of
the next in line. There is no need to complete a connection loop from the last unit in the chain, back to
the computer.
Note that with many Graphi-Q2s in line, the last units in the chain may respond more slowly, depending
on how “busy” the processors of your units are (for example, FBX processing is computation-intensive).
Also, commands from the computer controller may sometimes be executed faster than the update of
the screen that displays the parameters; in other words, the report of the execution of the command may
lag behind its actual completion. This time delay is an inherent limit of RS-232 serial connection speed.
7.3. INSTALLING THE SOFTWARE
Follow these simple instructions for installing the Sabine Remote Control Software for the Graphi-Q2:
1. Start Windows 95 or higher.
2. Insert the GRQ-Remote CD into your CD ROM drive.
3. Follow the instructions on the screen. The software will install on your computer.
NOTE: it is recommended that you allow the installer to place the Graphi-Q2 software in the
default folder location.
4. You now have a Program group window called GRQ Remote and an icon called
GRQ Remote.
NOTE: for updating software or re-flashing firmware, see section 8.10. Upgrading Graphi-Q2 Firmware
and Software.
TECH TIP
PC can’t find
Graphi-Q2...
Try these tips if you are
having difficulty con-
necting your Graphi-Q2
unit(s) to a Windows
PC.
1. Software Version. Make sure the software version installed in your computer is compatible with the
firmware version of your Graphi-Q2.
2. Check cable. You want a serial 9-pin, not a null modem.
3. COM Port. Make sure the COM Port selected is correct.
4. Refresh your COM Ports.
In Windows, click Start and select Settings, Control Panel.
Double click System.
Click on Hardware, Device Manager and open up Ports (COM & LPT).
Right click the COM Port for your Graphi-Q2 and select Remove (or Uninstall).
Your computer will verify your intent and then reboot. As it reboots, it will rebuild your COM Port file.
This will clean out previous settings for devices no longer attached to your computer and may allow
the Graphi-Q2 software to locate your unit(s).
NOTE:
COM Port Properties, Port Settings (Bits per second, Data bits, Parity, Stop bits & Flow control) are
controlled by the Graphi-Q2 Software and need not be adjusted.
Computer
Keyboard
Shortcuts
F8 Front Panel Defaults
F9 View Curves
F11 Link Table
F12 Reset Parameters
Ctrl-A Select GRQ #1
Ctrl-B Select GRQ #2, (etc.)
F2 FBX/Parametrics
F3 Comp/Limiter
F4 Digital Delay
F5 Global Parameters
F6 Stored Presets
F7 Contact Closure
Assignment
Shift-F1 Save snapshot #1
Shift-F2 Save snapshot #2
Shift-F3 Save snapshot #3
Ctrl-F1 Load snapshot #1
Ctrl -F2 Load snapshot #2
Ctrl-F3 Load snapshot #3
Escape Closes current screen