SABINE GRAPHI-Q2 Specifications Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 58
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
17
B1-GRQ-2-OpGuide-v1-060519.pmd
6.4.3. Adjustments Available Only with Remote Control
In addition to FBX, graphic, and high and low cut filters, your Graphi-Q2 can provide fully programmable
parametric filters. These filters are accessible only through GRQ-Remote software. Each channel of
your Graphi-Q2 can have up to 12 total filters, which can be configured as any combination of
parametric, fixed FBX, or dynamic FBX filters. See Section Eight for a complete look at GRQ Remote
Control Software.
6.5. COMPRESSOR/LIMITER CONTROLS
6.5.1. Front Panel Control
COMPRESSOR controls are located immediately to the right of the FBX
controls. Front panel controls consist of standard RATIO, THRESHOLD,
and GAIN makeup knobs, and two horizontal LED ladders showing channel
input gain on the top, and compressor gain reduction on the bottom row.
RATIO ranges from 1:1 to infinity: 1 (limiting).
The input level THRESHOLD, at which compression is engaged, can be
adjusted from -30 dBV to + 31.5 dBV.
The output gain of the compressor can be increased or decreased by
12 dB (this will also serve as the control for the overall output level of
the box).
Compressor KNEE, ATTACK, and RELEASE settings can only be set using
the Remote Control Software, and will default to the last settings programmed. (In addition, the remote
software will allow setting of a separate limiter threshold.) The factory default settings are attack = 15
mSec, release = 400 mSec, and knee = 20. These will remain in place until they are reprogrammed using
the software (see Section 9.5.2 for detailed information on Compressor/Limiters and Section 8.2.6 for
using the Graphi-Q2 Remote Control Software Compressor/Limiter control).
6.6. DIGITAL DELAY CONTROLS
6.6.1. Front Panel Control
DIGITAL DELAY controls are located to the right of the COMPRESSOR controls.
You may delay the output of the Graphi-Q2 audio signal by up to 999.96 mSec
(essentially one second) by using the up/down increment buttons just below the
display showing the amount of delay in mSec. Delay adjustments may be made
with 20-microsecond precision.
For the GRQ3121 model, the digital delay adjustments from the front panel will
affect ONLY the Output B signal. Output A will remain undelayed. You may of
course alter the delay setting for either output using the GRQ Remote Software
(see Section Eight). Note: For a complete discussion on using delays in sound
systems (and we mean complete), see Section 9.4.
When the Graphi-Q2 is first turned on, the firmware version will display briefly within the Digital Delay LED
screen. See Section 6.2.3 for how Tweek-n-Peek uses the Digital Delay LED.
6.7. BYPASS
6.7.1. Front Panel Control
BYPASS controls are located at the far right of the Graphi-Q2 front panel. Separate push
button controls allow independent bypass switching for graphic EQ, FBX, and digital
delay settings. For two-channel Graphi-Q2s, separate bypass controls are available for
each channel as well. When any feature is bypassed, the LED within the switch will
illuminate.
Turning off power to the Graphi-Q2 will place the entire unit in hardwire bypass. Please
note that a sudden bypass of FBX filters may result in a sudden burst of no-longer-filtered
feedback. It ain’t pretty when this happens, so proceed cautiously.
SECTION SIX: USING GRAPHI-Q2 CONTROLS
NOTE: Image shows
settings for bypassing
Compressor/Limiter.
1.38
TECH TIP
Unity Gain
Set Gain to 12:00
(straight up) for
unity gain.
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 57 58

Comments to this Manuals

No comments